5.6 Perform CIP or another suitable chemical cleaning protocol when any of the following
condions are encountered:
• normalized permeate ow rate drops 10-15% of its inial value;
• normalized conducvity of permeate increases 10-15% of inial value, raw water
conducvity remaining at the same level;
• normalized pressure drop along the membrane array rises 10-15% of its inial value.
5.7 Aer installing freshly cleaned membrane, perform 1 hour rinse discarding all permeate
and concentrate. If chemical cleaning fails to restore normalized ow or rejecon to design
specicaons, membrane element is irreparably fouled and has to be replaced.
5.8 To prevent microbial contaminaon, the unit should be operated for at least 1 hour a day.
In case 48 hours or longer shutdown is to occur, membrane should be treated with preservave
soluon. Preservave treatment is accomplished by circulang 1% sodium metabisulte soluon
through the membrane module for 30 minutes or by preparing metabisulte soluon of the above
strength in the module. Before resuming operaon of a machine that had been treated with
preservave, rinse the membrane.
Do not use supply water with over 0.1 mg/L of free chlorine without pre treatment with
acvated carbon or other means of dechlorinaon. Chlorine will destroy the membrane.
5.9 To replace sediment lter cartridge proceed as follows:
• remove the power from the unit;
• shut o water supply and relieve pressure;
• screw o lter bowl and remove it, taking care not to spill water on parts of the unit;
• remove spent cartridge from the bowl, place a clean one inside and screw the bowl back on.
5.10 To replace membrane element proceed as follows:
• remove the power from the unit;
• shut o water supply and relieve pressure;
• disconnect feed, permeate, and concentrate tube connecons at membrane module
outlets;
• unfasten clamps holding the pressure vessel and take down the vessel;
• remove caps from the pressure vessel;
• push the membrane element from the feed end towards the discharge end (in the
direcon of the arrow). Extract the membrane element by pulling it at the discharge end
of the vessel;
• install new membrane element, observing ow direcon as indicated by the arrow;
• fasten the caps and install the vessel back in place;
• re-connect tubes back to the vessel.