ow rate chart
Permeate ow rates are calculated under the following condions:
• 1.5…2.0 bar inuent water pressure
• 0 bar backpressure in the permeate line
• variable permeate recovery (shown on the top)
• 80% of the rated membrane ux
See the following secon for instrucons on process setup.
1 1
0
100
200
300
400
500
600
700
800
0 1 2 3 4 5 6 7 8 9 10 11 12
Permeate flow rate, l/h
Feed water total dissolved solids, g/l
25 °C
15 °C
5 °C
0
100
200
300
400
500
600
700
800
0 1 2 3 4 5 6 7 8 9 10 11 12
Permeate flow rate, l/h
Feed water total dissolved solids, g/l
25 °C
15 °C
5 °C
75%
70%
65%
60%
55%
50%
45%
40%
75%
70%
65%
60%
55%
50%
45%
40%
Permeate
recovery, %
Permeate
recovery, %
Figure 2.2 Ecoso MO12000BWTSS
ow rate chart
2.3. PRODUCT WATER CAPACITY CHARTS