INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
4. INSTALLATION REQUIREMENTS
• Installaon and setup of the unit should be undertaken by a qualied professional. Room
or area where the unit is to be installed must meet workplace standards of local building code.
• The unit must not be operated in outdoor environments. Do not expose to weather
condions (rain, temperature uctuaons, proximity of heang equipment, direct sunlight etc).
• Air at workplace should be free of corrosive vapors, airborne dust, and brous maer.
• To provide access to the unit for maintenance and repair purposes, respect the following
clearances between the unit and building structures: 500 mm to the le or right, 200 mm above.
• Electrical connecons must comply with local electrical code. Make sure to follow
applicable grounding and insulaon rules.
• Supply, drain, and delivery pipework must comply with local plumbing code and have
sucient ow capacity. Drain line of the unit must be separated from oor drain with an air gap.
• Construcon material or inside lining of permeate tank must be resistant to water
corrosion (e. g. stainless steel, polypropylene). Tank should be installed next to the unit.
• Anscalant pump sucon line length should not exceed 1.5 m. Refer to dosing pump’s
manual to adjust pump’s sengs if it has not been factory congured.
5. OPERATING REQUIREMENTS
5.1 Operator of the unit must strictly follow these guidelines and general electrical safety
precauons.
5.2 When operang the unit, ensure that pressure and ow rates are within specicaon
limits and that power supply is clean and uninterrupted.
5.3 Perform the following at least once a month:
• verify that pressure and ow rate parameters have not deviated (substanally);
• verify ghtness (absence of leaks) from connecons and visual integrity of parts.
5.4 In order to monitor performance of the RO machine, regularly keep record of
operaon and write down parameter readings. Use membrane manufacturer’s soware tools for
normalizaon to control for uctuaons of pressure, temperature, and other operang condions.
5.5 Change polypropylene cartridge when it has clogged. Pressure drop of 0.1 MPa or greater
on the sediment lter indicates that lter cartridge needs to be replaced as soon as possible.
If power supply cable or any other electrical wiring is damaged, it must be replaced by a
vendor’s service sta or similarly qualied person.