22
INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
A. WIRING DIAGRAM
DINREYKA × 0,150 м
2A 2A
FUSE
FUSE
STA R T
STOP
A1
A2
A1
A2
U1
V1
W1
W2
U2
V2
SROC50001U
Conductivity probe
ECOSOFT
OC5000EN
Controller
SUCO
0164-41341-3-013
high pressure switch
Float
Switch
SUCO
0164-42141-3-070
low feed pressure switch
SUCO
0166-40703-2-027
permeate pressure switch
Grundfos
CRN 1-36
pump
terminal box
220240 VAC, 50 Hz
power supply
Entry
Solenoid
Valve
VENT201404
Forward Flush Valve
WIRING DIAGRAM
ECOSOFT MO6500BWTSS, MO12000BWTSS
01: 3 × 2,5 mm² with ground
02: 3 × 2,5 mm² with ground
03: Float switch
04: 4 × 0,75 mm² with ground
05: 2 × 0,75 mm²
06: 4 × 0,75 mm² less ground
07: 2 × 0,75 mm²
08: 2 × 0,75 mm²
09: 2 × 0,75 mm²
10: 3 × 0,75 mm² less ground
: CABLE/WIRE
: CABLE/WIRE
11: Automac valve cable
12: Conducvity probe
13: 2,5 mm² brown
14: 2,5 mm² blue
15: 0,75 mm² blue
16: 0,75 mm² blue
17: 0,75 mm² brown
18: 0,75 mm² blue
ve r.
sheet
2020-11-20
1 / 1
01 02
03
04 05 06
07
08
09 10
11
12
13
14
15
16
17
18
PS1/1
PS1/2
PS3/1
PS3/2
EV1/1
EV1/2
EV1/G
A0/16
A0/17
A0/18
A0/23
A0/24
A0/29
A0/30
A0/31
A0/32
A0/6
A0/7
A0/8
A0/9
A0/12
A0/13
A0/14
A0/15
GND
GND
X2/5
X2/6
X2/7
X2/8
KM1/2
KM1/A2
KM1/4
X1/1
X1/2
X2/7
X2/8
X2/5
X2/6
X2/3
X2/4
X2/1
X2/2
X1/1
X1/2
KM1/1
KM1/A1
KM1/3
GND
GND
M1/W2
M1/W1
PS2/1
PS2/2
A0/1
A0/2
A0/3
A0/4
A0/5
A0/10
A0/11
A0/20
678
9 10
11 12
13
14
15
16 17 18
19 20
21 22
23
24
25 26
27
28 29 30 31 32
+Term-
Cond
Stop
P_in
P_max P_perm
Level
IN
RINSE
BYPASS
ALARM
PUMP AC 220V
1
2
3
4
5
5
L3
3
L2
1
L1
13
NO
T3
6
T2
4
T1
2
14
Bypass/
ush
solenoid
valve
External
stop
Float
switch
Dosing
pump
POWER
SUPPLY
TERMINALS
PUMP
CONTACTOR