EasyManua.ls Logo

Ecosoft MO6500BWTSS - Technical Specifications

Ecosoft MO6500BWTSS
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2021
5
INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
2.2. TECHNICAL SPECIFICATIONS
Table 1. Physical parameters
Model (SKU) MO6500BWTSS MO12000BWTSS
Rated capacity, LPH* 280 500
Membranes
1 × 4040 2 × 4040
Power consumpon 2.2 kW
Dimensions (
Width × Depth × Heigth
) 0.75 × 0.54 × 1.52 m
Approximate dry weight 130 kg 150 kg
Port sizes (feed water inlet, permeate
outlet, concentrate drain outlet)
½”
Working ow rates in typical operang condions**
Recycle ow rate 500…1000 l/h 500…1000 l/h
Drain ow rate 150…300 l/h 250…500 l/h
Permeate ow rate 250…400 l/h 450…700 l/h
Water consumpon per forward ush 40…60 l
* at feed water temperature = 25⁰С, TDS=10 g/l, 40% permeate recovery
** feed water must comply with requirements in Table 2. See Installaon and Startup secon
for a more specic instrucon on Permeate, Drain, and Recycle ow rates.
Table 2. Limitaons
Inuent water quality ***
Max. Total
Hardness
150 mg/l CaCO
3
(without an-
scalant)
Max. Iron,
Manganese, Hy-
drogen Sulde
0.05 mg/l
Max. Silica
20
mg/l
(without an-
scalant)
Max. Chemical
Oxygen Demand
(KMnO
4
)
5.0 mg/l O
2
Max. Total Sis-
solved Solids
10 000 mg/l
Max. Chlorine
(connuous)
0.1 mg/l
Operang parameters
Required supply
water pressure
0.2…0.4 MPa
Max. operang
pressure
2.5 MPa
Temperature of
water
5…30 °C Electrical power
230 V, 50 Hz
(1 phase)
***Some limitaons may not apply if using anscalant, oxygen scavenger, or
other type of chemical pretreatment.
Tap feed water must be
pre-ltered from ne
parcles and chlorine
before entering the
RO system. Well water may contain
impuries such as hardness, iron,
manganese, silica, hydrogen sulde
that can quickly lead to membrane
failure. Some of these challenges
can be addressed by using injecon
of anscalant. Perform a detailed
laboratory analysis of your well
water and consult a water treatment
specialist to see if you need addional
equipment for treang your well water.