This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2021
18
INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
Conguraon sengs are stored in non-volale memory. Access to each submenu is protected
with passcode. To enter conguraon menu, hold STOP for 8 seconds. In the menu, eding and
storing values is helped by ashing cursor. START buon moves cursor one posion to the right,
STOP buon increments selected digit by one, cycles between opons, or scrolls to the next
screen when the cursor is at the ‘>’ symbol.
*During the rst run of the R.O. unit, the parameter can be increased to the maximum value in order to vent
the air and ll the system with water. Make sure to revert it back to the factory seng of 10 sec.
8.4. PROGRAM SETTINGS
MENU FACTORY SETTINGS
SETTINGS
1. SETTINGS AND CALIBRATION PASSCODE PROMPT 0000
1.0 Language English
1.1 High pressure pump delay, s 10 s*
1.2 Forward Flush 1 duraon, s 60 s
1.3 Forward Flush 2 duraon, s 0 s
1.4 High pressure pump power during Forward Flush 2, on/o o
1.5 Frequency of periodic Forward Flush in Service, h 4 hour
1.6 Frequency of periodic Forward Flush in Standby, h 24 hour
1.7 Read low feed pressure during Forward Flush, on/o on
1.8 Low feed pressure switch, NO/NC NC
1.9 Low feed pressure Fault delay, s 3 s
1.10 High feed pressure switch, NO/NC NO
1.11 Permeate backpressure switch, NO/NC NC
1.12 Backpressure Standby delay, s 1 s
1.13 Tank level switch, NO/NC NC
1.14 Tank level Standby delay, s 1 s
1.15 Display TDS in ppm o
1.16 Permeate conducvity Fault threshold, μS/cm 0 μS/cm
1.17 Permeate conducvity Fault delay, s 0
1.18 Display temperature C
1.19 New sengs and calibraon passcode -
2. SETTINGS AND CALIBRATION PASSCODE PROMPT 0000
2.1 First point value, μS/cm -
2.2 Second point value, μS/cm -
3. MAINTENANCE PASSCODE PROMPT 0000
3.1 Schedule maintenance stop, on/o o
3.2 Scheduled stop period, h (if 3.1 is set to ‘on’) 500 h
3.3 New maintenance passcode