INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
Conguraon sengs are stored in non-volale memory. Access to each submenu is protected
with passcode. To enter conguraon menu, hold STOP for 8 seconds. In the menu, eding and
storing values is helped by ashing cursor. START buon moves cursor one posion to the right,
STOP buon increments selected digit by one, cycles between opons, or scrolls to the next
screen when the cursor is at the ‘>’ symbol.
*During the rst run of the R.O. unit, the parameter can be increased to the maximum value in order to vent
the air and ll the system with water. Make sure to revert it back to the factory seng of 10 sec.
8.4. PROGRAM SETTINGS
MENU FACTORY SETTINGS
SETTINGS
1. SETTINGS AND CALIBRATION PASSCODE PROMPT 0000
1.0 Language English
1.1 High pressure pump delay, s 10 s*
1.2 Forward Flush 1 duraon, s 60 s
1.3 Forward Flush 2 duraon, s 0 s
1.4 High pressure pump power during Forward Flush 2, on/o o
1.5 Frequency of periodic Forward Flush in Service, h 4 hour
1.6 Frequency of periodic Forward Flush in Standby, h 24 hour
1.7 Read low feed pressure during Forward Flush, on/o on
1.8 Low feed pressure switch, NO/NC NC
1.9 Low feed pressure Fault delay, s 3 s
1.10 High feed pressure switch, NO/NC NO
1.11 Permeate backpressure switch, NO/NC NC
1.12 Backpressure Standby delay, s 1 s
1.13 Tank level switch, NO/NC NC
1.14 Tank level Standby delay, s 1 s
1.15 Display TDS in ppm o
1.16 Permeate conducvity Fault threshold, μS/cm 0 μS/cm
1.17 Permeate conducvity Fault delay, s 0
1.18 Display temperature C
1.19 New sengs and calibraon passcode -
2. SETTINGS AND CALIBRATION PASSCODE PROMPT 0000
2.1 First point value, μS/cm -
2.2 Second point value, μS/cm -
3. MAINTENANCE PASSCODE PROMPT 0000
3.1 Schedule maintenance stop, on/o o
3.2 Scheduled stop period, h (if 3.1 is set to ‘on’) 500 h
3.3 New maintenance passcode