19
INSTRUCTION MANUAL ECOSOFT RO SYSTEM
MO6500BWTSS
1. Sengs
Hold STOP for 8 seconds to launch menu prompt. Push START to enter Sengs submenu.
Enter passcode in the prompt. Factory passcode is ‘0000’.
1.0 Language
Choose language to display operaon informaon & menu. Avialable languages include English
& Russian.
1.1 High pressure pump delay
Enter length of interval between opening the entry valve and starng the pump when the unit is
going into Service (0…255 seconds).
1.2 Forward Flush 1 duraon
Enter length of Forward Flush 1 (0…255 seconds). Forward Flush 1 will not be performed if the
parameter is set to zero.
1.3 Forward Flush 2 duraon
Enter length of Forward Flush 2 (0…255 seconds). Forward Flush 2 will not be performed if the
parameter is set to zero. Default seng is zero (Forward Flush 2 disabled).
1.4 High pressure pump power during Forward Flush 2
This seng species whether the high pressure pump will be powered during Forward Flush 2
(on/o).
1.5 Frequency of periodic Forward Flush in Service
This seng determines how oen Service mode is interrupted to run forward ush sequence
(once in 0…255 hours).
1.6 Frequency of periodic Forward Flush in Standby
This seng determines how oen Standby mode is interrupted to run forward ush sequence
(once in 0…255 hours).
1.7 Read low feed pressure during Forward Flush
This seng species if low feed pressure switch status will be read by the controller during
forward ush. If set to ‘o, low feed pressure situaon will not bring about Fault mode.
1.8 Low feed pressure switch
This seng species whether low feed pressure switch is normally closed (NC) or normally open
(NO) type.
1.9 Low feed pressure Fault delay
Specify the length of me before the controller goes into Fault mode if low feed pressure condion
occurs (0…255 seconds). The pump will connue to run for this many seconds before Fault mode is
switched to. If set to 0, pump will stop running immediately aer low feed pressure occurs.