SPECIFICATIONS EDGE30 (CONT.)
Gas Supply Specifications
Modulating Burner
Natural Gas Supply (NAT)
Orifice Diameter ........................................ 0.120”
Supply Pressure ....................................... 6-8” WC
Manifold Pressure ..................................... 4.5” WC
MAXIMUM BTU .......................................... 50,000 BTU
Liquefied Petroleum (LP Supply)
Orifice diameter ........................................ 0.081”
Supply Pressure ....................................... 11-13” WC
Manifold Pressure ..................................... 10” WC
MAXIMUM BTU .......................................... 50,000 BTU