8) Replace the thermocouple, starting at the gas valve. Then reinstall at the igniter assembly with the
nut while observing exposed length indicated.
NOTE: The exposed portion of the thermocouple measures 1 7/16” (36 mm).
9) Follow the above steps in reverse to reinstall the necessary components.
Replacing the Rear Infrared Burner Valve
Tools Needed:
• Phillips Screwdriver
1) Remove the drip tray.
2) Unscrew the Phillips screws on the left and right sides of the control panel as well as the screw
that axes the gas manifold on the right side of the rebox.
3) At the central control panel, remove the control knobs, then remove the 2 screws that attach each
knob bezel and remove them.