Motor output rang - connuous 0.16 kW
Motor electrical supply Single phase
Table 5
Electrical data
Pump
Nominal supply (V) Frequency (Hz) Full load current (A)
E2M0.7 100 - 115 50 1.8
100 - 120 60 1.9
200 - 230 50 0.85
200 - 240 60 1.0
E2M1 and E2M1.5 100 - 115 50 3.1
100 - 120 60 3.0
200 - 230 50 1.3
200 - 230 60 1.4
Table 6
Recommended regional supply protecon
Area
Voltage (V) Rang (A)
UK 230 6
Europe 230 6
USA 110 10
Japan 100 10
3.5.1 Electrical cables
Recommended cord sets and fuses for regional requirements.
Table 7
Recommended cord sets
Descripon Rang Coupler type Item number
Cord set
assembly, UK
Cable style = H05VV-F, 3 x 1.0 mm
2
,
300 V,
70 °C, maximum length of 2.0 metres
Plug type = BS1363 UK plug
Appliance coupler = IEC60320 style C14
Fuse type = BS1363 10 Amp fuse, to an
IEC60320 style
Straight entry A50505000
Cord set
assembly,
Europe
Cable style = H05VV-F, 3 x 1.0 mm
2
,
300 V, 70 °C, maximum length of
2.0 metres
Plug type = European Schuko VDE
approved, 16 A 250 V rated with dual
earthing contact
Appliance coupler = IEC60320 style C14
Straight entry A50506000
Page 15
A37132880_F - Technical data

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M1.5 and is the answer not in the manual?

Edwards E2M1.5 Specifications

General IconGeneral
BrandEdwards
ModelE2M1.5
CategoryWater Pump
LanguageEnglish

Related product manuals