2. Introducon
2.1 Scope and denions
This manual provides installaon, operaon and maintenance instrucons for our rotary
vacuum pumps. The pump must be used as specied in this manual. Read this manual
before installing and operang the pump.
2.2 ATEX direcve implicaons
This equipment is designed to meet the requirements of Group II Category 3 equipment
in accordance with Direcve 2014/34/EU of the European Parliament and the Council of
26th February 2014 on the approximaon of the laws of the Member States concerning
equipment and protecve systems intended for use in potenally explosive
atmospheres. (The ATEX Direcve).
The ATEX Category 3 applies in respect of potenal ignion sources internal to the
equipment. An ATEX Category has not been assigned in respect of potenal ignion
sources on the outside of the equipment as the equipment has not been designed for
use where there is an external potenally explosive atmosphere. There is no potenal
source of ignion within the pump during normal operaon but there may be potenal
sources of ignion under condions of predictable and rare malfuncon as dened in
the Direcve.
There is no potenal source of ignion within the pump during normal operaon but
there may be potenal sources of ignion under condions of predictable and rare
malfuncon as dened in the Direcve. Accordingly, although the pump is designed to
pump ammable materials and mixtures, operang procedures should ensure that
under all normal and reasonably predictable condions, these materials and mixtures
are not within explosive limits. Category 3 is considered appropriate for the avoidance of
ignion in the case of a rare malfuncon which allows ammable materials or mixtures
to pass through the pump while within their explosive limits.
When ammable or pyrophoric materials are present within the equipment:
Do not allow air to enter the equipment.
Ensure that the system is leak ght.
For further informaon, please contact us: refer to our website
www.edwardsvacuum.com for details of your nearest company.
2.3 Descripon
The pump is shown in Figure: General view of the pump on page 11.
Page 9
A37132880_F - Introducon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M1.5 and is the answer not in the manual?

Edwards E2M1.5 Specifications

General IconGeneral
BrandEdwards
ModelE2M1.5
CategoryWater Pump
LanguageEnglish

Related product manuals