EasyManuals Logo

Edwards E2M1.5 User Manual

Edwards E2M1.5
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
6. Maintenance
6.1 Safety informaon
WARNING:
Allow the pump to cool (so that it is at a safe temperature for skin contact) before
starng maintenance work. Make sure the pump is switched o in case the thermal
overload device restarts the pump.
WARNING:
Obey the safety instrucons given below and take note of appropriate precauons.
Failure to do so can cause injury to people and damage to equipment.
A suitably trained and supervised technician must maintain the pump. Obey your
local and naonal safety requirements.
Ensure that the maintenance technician is familiar with the safety procedures
which relate to the pump-oil and the products processed by the pumping-system.
Isolate the pump and other components in the pumping system from the electrical
supply so that they cannot be operated accidentally.
Aer maintenance is completed, recheck the pump rotaon direcon if the
electrical supply has been disconnected.
Do not reuse O-rings and seals if they are damaged.
The pump and its uid will be contaminated with the process chemicals that have
been pumped during operaon. Ensure that the pump is decontaminated before
maintenance and that adequate precauons are taken to protect people from the
eects of dangerous substances if contaminaon has occurred.
Do not touch or inhale the thermal breakdown products of uorinated materials
which may be present if the pump has been heated to 260 °C (500 °F) and above.
These breakdown products are very dangerous. Fluorinated materials in the pump
may include oils, greases and seals. The pump may have overheated if it was
misused, if it malfunconed or if it was in a re. Our Material Safety Data Sheets
for uorinated materials used in the pump are available on request: contact us or
your supplier.
Leak-test the system aer maintenance work is complete if any vacuum or exhaust
joints were connected or disconnected, seal any leaks found.
6.2 Maintenance plan
The plan shown in details the roune maintenance operaons necessary to maintain the
pump in normal use. Instrucons for each operaon are given in the secon shown.
More frequent maintenance may be required if the pump is used to process corrosive or
abrasive gases and vapours, in these circumstances, we recommend you to replace the
pump seals every year. If necessary, adjust the maintenance plan according to
experience.
Page 27
A37132880_F - Maintenance

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M1.5 and is the answer not in the manual?

Edwards E2M1.5 Specifications

General IconGeneral
BrandEdwards
ModelE2M1.5
CategoryWater Pump
LanguageEnglish

Related product manuals