Introduction
A419-00-880 Issue F
Table 3 - EPX L pump labelling information (Refer to Figure 4)
Number Label Name Description
1 Pump details This provides specific information about the pump including: pump
type; code number; serial number; pump weight; year of
manufacture; and name and address of the manufacturer. It also
includes electrical supply requirements, and compliance marks.
2 Power The power LED. See Tab le 1 for details.
3 Run The run LED. See Tab l e 1 for details.
4 Warning The warning LED. See Tab le 1 for details.
5 Alarm The alarm LED. See Ta b le 1 for details.
6 Warning - risk of electric
shock
Do not remove cover until 4 minutes after disconnection of the
power.
7 Warning - risk of electric
shock
Do not remove cover until 4 minutes after disconnection of the
power.
8 Status LED label Status LED label.
9 and 10 Lifting point The pump must be lifted using the eyebolts on the pump and
suitable lifting equipment.
11 Warning - risk of high
temperature
Surface temperatures can exceed 65
o
C during pump operation.
12 Direction of rotation Arrow shows the correct direction of rotation of the rotor.
13 Warning - danger of injury
from rotating parts
Turn off and lock-out all power prior to servicing.
14 Water in The cooling water supply pipeline connects to the pump at this
location.
15 Protective earth stud This equipment must have a second protective earth. See
Section 3.10.
16 Pump interface Tool Interface Module (TIM) fits in this position. The pump may be
controlled through this. See Section 3.11.
17 Warning - risk of electric
shock
Do not remove cover until 4 minutes after disconnection of the
power.
18 Warning - risk of electric
shock
Do not remove cover until 4 minutes after disconnection of the
power.
19 Warning - thermal shock If the pump has overheated or the cooling water has failed,
connecting cooling water to a hot pump will cause severe damage to
the pump.
Always allow the pump to cool for at least 20 minutes before
connecting cooling water.
20 Water out The cooling water return pipeline connects to the pump at this
location.
21 Product label Product name.