A419-00-880 Issue F
Page 16 © Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
2.3 Electrical data
Table 8 - Electrical data
Electrical items Reference data
Electrical supply 200/208 V, 50/60 Hz, 400 V 50/60 Hz 3-phase
Voltage tolerance ±10%
Electrical power
Maximum Power 3.0 kW
Nominal Power at Ultimate (EPX)
L-variant 1.4 kW
N-variant 1.6 kW
Nominal Power at Ultimate (EPX twin)
L-variant 2.30 kW
N-variant 2.55 kW
Fuse/ isolator rating
*
*
Maximum recommended fuse rating; requires a multipole isolator with a minimum contact gap of 3 mm.
The mains disconnect device AIC (Amperes Interrupting Capacity) must be rated to at least 10 000 A.
See clause 13 of SEMI S2 - 0200 and SEMI S8 for further details.
200 V 17.5 A current limiting time delay Class CC fuse, rated 600 V
400 V 10 A current limiting time delay Class CC fuse, rated 600 V
Installation (overvoltage) category Class II
Pollution degree 2
Minimum protective earth (ground) cable rating 32 A
Electrical supply interface Per customer specification
Power cable 4 core terminated with 2.5 mm
2
bootlace ferrules
TIM
Parallel pump interface As per TIM interface supplied (refer to Section 3.11)
Nominal voltage rating 24 V
Shut-down thermal snap-switch
Opening temperature 70
o
C, 158
o
F
Closing temperature 59
o
C, 138
o
F