Table
14
-
Miscellaneous
fault
conditions
Indicator
Host
fail
signal.
Supplies
fail
signal
to
the
host
interface
when
any
of
the
following
occur:
Host
wam
signal.
Supplies
wam
signal
to
the
process
tool
when
any
of
the
following
occur:
Temperature
controller
process
value
blinks.
Failure
to
cool.
Possible
causes
Unit
in
STOP
mode
FACILITY
POWER
Fail
FACILITY
WATER
Fail
CIRCUIT
BREAKER
Fail
COMPRESSOR
Fail
TEMPERATURE
Fail
FLOW
Fail
Coolant
LOW
LEVEL
FAULT
Coolant
NORMAL
LEVEL
OVER-FILL
Coolant
LOW
LEVEL
RTD
wired
incorrectly
to
the
interface
connector
J72J3.
Terminals
4
and
5 are
not
linked
on
the
interface
connector
J72J3.
Incorrect
RTD
type
being
utilized.
Temperature
controller
parameters
are
not
set
to
factory
defaults.
Main
cooling
solenoid
valve
(SVl)fail.
Relay
board
failure.
Moisture
is
in
the
system.
Action
Refer
to
the
"Faults
indicated
by
the
front
panel
LED
indicators"
on
page
44.
Refer
to
the
"Faults
indicated
by
the
front
panel
LED
indicators"
on
page
44
Verify
that
the
remote
RTD
is
wired
correctly.
Refer
to
the
"Remote
Interface
wiring
schematic"
on page
56.
Verify
that
terminals
4 and
5
on
connector
J72J3
are
linked.
Refer
to
the
"Remote
Interface
wiring
schematic"
on
page
56.
Verily
that
the
RTD
is
100
ohm
European.
Verify
temperature
controller
PID
settings.
Refer
to
the
"Temperature
controller"
portion
of
the
System
Check
on
page
21.
Verify
24
VAC
is
present
between
wire
#16
(J4-5)
on
the
relay
board
and
wire
#4
(TB1).
To
do
this,
opening
of
the
electrical
drawer
is
necessary.
This
will
activate
the
drawer
interlock
switch
and
shut
the
TCU
40/80
down.
Notify
the
tool
operator
prior
to
opening
the
electrical
drawer.
Verify
current
draw
of
the
solenoid
is
not
above
1
amp.
Verify
that
the
resistance
of
the
coil
is
about
8
Q.
If
necessary,
replace
the
coil
(EHVI
part
no.
P3303O3OO).
Verify
that
the
main
cooling
relay
(CR15)
comes
on
when
the
unit
is
in
cooling
mode.
Verify
that
the
moisture
indicator
in
the
sight
glass
is
green.
If
it
appears
yellow
in
color
remove
power
from
the
unit
and
notify
an
Edwards
service
representative.
Hazard
Type
3
Type
3
Type
2
Type
4
Type
3
Type
2
TCU
40/80
Temperature
Control
Unit
49