15. Specications
Model: efergy e
2
Frequency: 433 MHz
Transmission intervals: 6 – 12 – 18 seconds
Range: > 40 metres
Measuring voltage: 110 – 400 V
Measuring current: 50 mA – 95 A
Accuracy: > 90 %
Backlight: Activated between 18:00 and 06:00
Power supply: Display unit (receiver): Batteries: 3 x AA/LR6 (not included)
Transmitter: Batteries: 3 x AAA/LR03 (not included)
14. Disposal
Follow local ordinances when disposing of this product. If you are unsure of
how to dispose of this product, please contact your local authority.
How do I clear the monitor display?
Press and hold in both the [TIME PERIOD] and [UNIT SET] buttons simultaneously for 3 seconds
until CLr appears on the display.
Does the electricity monitor work with Windows 7?
The electricity monitor is compatible with both the 32-bit and 64-bit version of Windows 7.

Other manuals for Efergy E2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Efergy E2 and is the answer not in the manual?

Efergy E2 Specifications

Transmission IconTransmission
frequency433.52 MHz
transmission time6s, 12s, 18s
transmission range40m-70m
Voltage and Current IconVoltage and Current
voltage range (in the sensor)110V-400V
measuring current50mA-95A
accuracy>90%