EFKA DA320G5351
26
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter Designation Unit Limits Preset for Ind.
max min 100 220 680 1000
12 = Sewing foot lifting with pedal in position 0
(neutral)
13 = High lift for walking foot with speed limitation
n10 (operational mode not stored)
14 = High lift for walking foot (flip-flop 1) with
speed limitation n10
15 = Sewing foot pressure (NFD)
16 = Intermediate backtack
17 = Backtack suppression / recall
18 = Thread tension reduction
19 = Reset bobbin thread monitor if parameter
085 = >0
20 = Handwheel running in the direction of
rotation according to the setting of
parameter 161
21 = Handwheel running in the opposite direction
of rotation according to the setting of
parameter 161
22 = Stitch length (STL)
23 = Roller
24 = No function
25 = Fixed speed DB2000
26 = Speed limitation n11 (DB3000)
27 = Speed limitation n10 (DB2000)
28 = External light barrier (according to setting
of parameter 131)
29 = Single stitch with stitch length switching
30 = Emergency stop
31..38 = No function
39 = Switch to the next pattern in TEACH IN
40 = Switch back to the previous pattern in
TEACH IN
41..45 = No function
46 = Key for output A
47 = Key for output B
48 = Signal A1 is issued
49 = Signal A1 switchable as flip-flop
50 = No function
51 = Signal A2 is issued
52 = Signal A2 switchable as flip-flop
53..69 = No function
241 in2 Selection of input function on socket A/11 for 69 0 7 7 9 9 A
input 2
0 = No function
All other functions of the keys as with parameter 240
242 in3 Selection of input function on socket A/6 for 69 0 2 2 2 2 A
input 3
0 = No function
All other functions of the keys as with parameter 240
243 in4 Selection of input function on socket A/8 for 69 0 46 46 46 46 A
input 4
0 = No function
All other functions of the keys as with parameter 240
244 in5 Selection of input function on socket A/5 for 69 0 16 16 16 16 A
input 5
0 = No function
All other functions of the keys as with parameter 240
245 in6 Selection of input function on socket A/12 for 69 0 18 18 19 18 A
input 6
0 = No function
All other functions of the keys as with parameter 240