9 Operating Elements of the V810 Control Panel
P
+
A1 2 3 4
variocontrol 810
KL2185
B
-
1
E
The V810 control panel is supplied with slide-in strip no. 1 above the keys. For different functions the strip can be replaced
with a different one supplied with the control panel. Set parameter 291 in this case. See also V810 / V820 instruction
manual!
Function Key Assignment
Key P = Call or exit of programming mode
Key E = Enter key for modifications in the programming mode
Key + = Increase of the value indicated in the programming mode
Key - = Decrease of the value indicated in the programming mode
Key 1 = Start backtack SINGLE / DOUBLE / OFF
Key 2 = End backtack SINGLE / DOUBLE / OFF
Key 3 = Automatic sewing foot lift after thread trimming ON / OFF
Automatic sewing foot lift at stop in the seam ON / OFF
Key 4 = Basic position needle down (POSITION 1) / needle up (POSITION 2)
Key A= Key for backtack suppression/recall
(Different input functions can be assigned to key A using parameter 293)
Key B= Key for needle up or shift key in the programming mode
(Different input functions can be assigned to key B using parameter 294)