a rate of about once per second. If there is no change to the load value, no data will
be output.
When the system is first turned on, it will output a lead section of six lines. The first
five of these are the system's owner identification info and must be factory set. If no
instructions were given at the time of ordering, these lines will be blank. Each line
includes up to 60 characters.
A printed data record line includes the following:
1. The load (up to 5 digits)
2. The unit of measurement
3. TARE mode: NET or GROSS
4. Function: LOAD = reading taking directly from indicator.
MAX (PEAK HOLD) = max value reading
TOT. # = reading from totalizer memory. Value and number of
loads
D.L. 1 = reading #1 from Data Logger memory
D.L. 2 = reading #2 from Data Logger memory
D.L. etc.
5. DATE & TIME
Baud Rate Selection
Press and hold the Menu/OK button until a beep is heard
Use the arrow keys▲▼ to select RS232 from the options menu and press OK.
Use the arrow keys▲▼ to select BAUD.R, and press OK
The display will show the current baud rate in use. Use the arrow keys again to scroll
through the available rates:
115,200 – 38,400 – 19,200 – 9,600
Press Menu/OK. The display will show OK, the selected baud rate, and then revert
back to the options menu. Press ESC to exit the options menu.