11. Troubleshooting guide
Faults Cause Remedy
The equipment
does not start
- Power supply not connected
- Floating switch does trigger
- Check power supply
- Raise position of oating switch
The equipment
does not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with water jet
- Unkink the hose
The equipment
does not cut out
- Floating switch cannot sink - Place equipment correctly on shaft
bottom
Insucient pumping
rate
- Intake sieve clogged
- Performance reduced due to heavi-
ly contaminated and abrasive water
impurities
- Clean intake sieve
- Clean equipment and replace wear
parts
The equipment swit-
ches o after briey
running
- Motor circuit-breaker switches the
equipment o due to excessive wa-
ter contamination
- Water temperature too high; motor
circuit-breaker switches the equip-
ment o
- Unplug power plug and clean
equipment and shaft
- Ensure that maximum permissible
water temperature (35 °C) is not
exceeded
For EU countries only
Never place any electric power tools in your household refuse.
To comply with European Directive 2012/19/EC concerning old electric and electronic equipment and
its implementation in national laws, old electric power tools have to be separated from other waste and
disposed of in an environment-friendly fashion, e.g. by taking to a recycling depot.
Recycling alternative to the return request:
As an alternative to returning the equipment to the manufacturer, the owner of the electrical equipment
must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment.
The old equipment can be returned to a suitable collection point that will dispose of the equipment in
accordance with the national recycling and waste disposal regulations. This does not apply to any ac-
cessories or aids without electrical components supplied with the old equipment.
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac-
companying products is permitted only with the express consent of the Einhell Germany AG.
Subject to technical changes
Anl_GC_DP_3325_SPK13.indb 18Anl_GC_DP_3325_SPK13.indb 18 21.01.2021 13:31:3621.01.2021 13:31:36

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GC-DP 3325 and is the answer not in the manual?

EINHELL GC-DP 3325 Specifications

General IconGeneral
TypeImpulse pump
Proper useGarden, Pond
Product colorBlack, Red
Suitable for indoor useNo
Suitable for outdoor useYes
Flow rate9500 l/h
Maximum suction height7 m
Maximum delivery height6 m
Maximum operating pressure- bar
Maximum input water temperature35 °C
AC input voltage230 V
Power cable typeH05RN-F
Power source typeAC
AC input frequency50 Hz
Quantity per pack1 pc(s)
Cable length10 m
Weight and Dimensions IconWeight and Dimensions
Depth226 mm
Width172 mm
Height313 mm
Weight2870 g