- 12 -
The pump shaft should be large enough.
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 230 V ~ 50 Hz. Make sure that the
socket-outlet is su ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
Danger!
To rule out danger, this work must be left strictly to
a specialist electrician or Customer Service.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
230 V ~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run
dry.
To switch off the equipment, pull the power
plug out of the socket outlet.
Setting the On/O switching point:
The ON/OFF switching point of the oating switch
can be adjusted by shifting the oating switch in
the oating switch notched holder (Fig. 3/Item 5).
The floating switch must be fitted so that the
switching point height: ON and the switch
point height: OFF can be reached easily and
with little force. Check this by placing the
equipment in a container filled with water
and carefully raising and lowering the floating
switch with your hand. You can then see whe-
ther the equipment switches on and off.
Make sure that the distance between the floa-
ting switch head and the cable holder is not
too smaller than 10 cm. If the distance is too
small, there is no guarantee that the equip-
ment will work correctly.
When adjusting the floating switch, make
sure that the floating switch does not touch
the bottom before the equipment is switched
off. Important! Risk of dry running.
Manual operation:
Mount the oating switch as illustrated in Figure 1.
The equipment will then run continuously. To pre-
vent dry running, this operating mode is allowed
only under supervision. The equipment must be
switched o (pull out the power plug) as soon as
no more water is emitted from the discharge line.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
Anl_SA_GC_DP_7835_SPK8.indb 12Anl_SA_GC_DP_7835_SPK8.indb 12 28.04.16 09:3928.04.16 09:39

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GC-DP 7835 and is the answer not in the manual?

EINHELL GC-DP 7835 Specifications

General IconGeneral
Cord length10 m
Product colorBlack, Red
Housing materialPlastic
Carrying handle(s)Yes
Motor power- hp
Pumping capacity15700 l/h
Maximum delivery height8 m
Depth of immersion (max)7 m
Solid particles size (max)35 mm
Maximum input water temperature35 °C
AC input voltage230 V
AC input frequency50 Hz
Quantity1
Weight and Dimensions IconWeight and Dimensions
Weight5200 g
Package depth220 mm
Package width180 mm
Package height380 mm
Package weight5700 g