When installing, never hang the equipment by the
discharge line or by the power cable. The equip-
ment must be hung up with the provided carry
handle or it must rest on the bottom of the shaft.
To ensure that the equipment works properly, the
bottom of the shaft always must be free of sludge
and other accumulations of dirt. If the water level
is too low, the sludge in the shaft can quickly dry
out and hinder the equipment from starting. It is
necessary therefore to check the equipment regu-
larly (carry out trial start-ups).
The pump shaft should be large enough.
5.2 Mains connection
Danger!
The equipment you have purchased comes with
an earthing-pin plug. The equipment is designed
for connection to a socket outlet with earthing
contact for 220-240 V~ 50 Hz. Make sure that the
socket-outlet is su ciently fused (at least 6 A)
and in good working order. Insert the power plug
in the socket-outlet and the equipment is ready
for operation.
6. Operation
You can put the equipment into operation after
you have thoroughly read the installation and ope-
rating instructions. Pay attention to the following
points:
Make sure that the equipment is set up secu-
rely.
Check that the discharge line is fitted correct-
ly.
Make sure that the electrical connection is
220-240 V~ 50 Hz.
Check that the electrical socket-outlet is in
good working order.
Make sure that no moisture or water can ever
reach the power connection.
Make sure that the equipment does not run
dry.
To switch off the equipment, pull the power
plug out of the socket outlet.
Setting the On/O switching point:
The ON/OFF switching point of the oating switch
can be adjusted by shifting the oating switch in
the oating switch notched holder (Fig. 2/Item 5).
The floating switch must be fitted so that the
switching point height: ON and the switch
point height: OFF can be reached easily and
with little force. Check this by placing the
equipment in a container filled with water
and carefully raising and lowering the floating
switch with your hand. You can then see whe-
ther the equipment switches on and off.
Make sure that the distance between the floa-
ting switch head and the cable holder is not
too smaller than 10 cm. If the distance is too
small, there is no guarantee that the equip-
ment will work correctly.
When adjusting the floating switch, make
sure that the floating switch does not touch
the bottom before the equipment is switched
off. Important! Risk of dry running.
7. Replacing the power cable
Danger!
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning, maintenance and
ordering of spare parts
Danger!
Unplug the power plug prior to any mainte-
nance work.
For mobile applications, the equipment
should be cleaned with clear water after every
usage.
For stationary installation, it is recommended
that you check the floating switch for proper
operation every three months.
Use a water jet to remove any lint or fibrous
particles that may have become trapped in
the housing.
Remove sludge from the shaft bottom and
clean the shaft walls every 3 months.
Use clear water to remove deposits from the
floating switch.
If the pump has been operated with subs-
tances that tend to form deposits, it will need
to be cleaned with a powerful water jet after
use to prevent any deposits or incrustations
forming that could otherwise affect the perfor-
mance characteristics of the pump.
Anl_GE_DP_900_Cut_SPK13.indb 16 02.11.2021 14:20:54
www.sidirika.nikolaidi.gr

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL GE-DP 900 Cut and is the answer not in the manual?

EINHELL GE-DP 900 Cut Specifications

General IconGeneral
Type-
Proper usePond
Product colorBlack, Red
Suitable for indoor useNo
Suitable for outdoor useYes
AC input voltage220 - 240 V
Power source typeAC
AC input frequency50 Hz
Maximum delivery height11.5 m
Maximum input water temperature35 °C
Package depth320 mm
Package width492 mm
Package height300 mm
Package weight15300 g
Quantity per pack1 pc(s)
Cable length10 m
Weight and Dimensions IconWeight and Dimensions
Weight12800 g