- 31 -
STEP 2
Connect the female splitter connector to a header located on the
motherboard or fan controller. If possible, use a header designated for
the CPU.
STEP 2
Female Splitter Header
EK-AT X
Bridging Plug
Power supply ATX Cable
RECOMMENDED FILLING AND LEAK
TESTING PROCEDURE
STEP 1
It is mandatory to do the following:
1. Disconnect all PSU power connectors on your PC (4/8-pin EPS,
24-pin ATX, PCIexpress power, SATA power),
2. Plug the EK-ATX Bridging Plug (enclosed) into the 24-pin ATX PSU
cable, which allows jump-starting your computer.
This procedure requires only the pump to be connected to the power
supply (PSU). Everything else needs to be disconnected!
This Step must be done to prepare the power supply for the
pump, so you can fill the water cooling loop with coolant
and run the leak test.
Your system is now ready to be charged for the first time.
STEP 1