FILLING THE SYSTEM FOR THE FIRST TIME
STEP 1
Preparing the Cooling Liquid.
The coolant comes in the concentrated form. To prepare the cooling
liquid, you must take 100mL of clear coolant concentrate (comes
enclosed with the Kit) and mix it with 900mL of distilled water.
Make sure you mix it properly before pouring it into your water
cooling loop.
Store the remaining liquid in the original bottle. Do not use
any food or beverage containers!
STEP 2
Remove the top cover of your reservoir by unscrewing it in a counter-
clockwise direction.
It is recommended to protect the exposed hardware with a
few paper towels in case there is a leak, or you accidentally
spill the coolant while pouring it.
Take the pre-mixed coolant and pour it into the reservoir until the
coolant level is about 2cm below the top.
STEP 3
Please check if you have plugged in the EK-ATX Bridging
Plug and EK-Cable Pump Testing Adapter correctly.
Refer to the chapter: Recommended Filling and Leak-
Testing Procedure.
Turn the power supply on for a brief moment to check if only the
pump is running.
STEP 1
STEP 2 STEP 3
Coolant
Concentrate
Distilled
Water