MEDIBURN30 17 D-115 Rev 010
www.elastec.com
Once the cycle is complete and the cool-down phase has taken place, the door
lock will disengage. The unit can then be loaded for another cycle. At this
time, the unit is still hot. Care should be taken to avoid touching the surfaces of
the burn chambers. Gloves should be worn at all times.
If refuse from a previous cycle remains in the primary chamber, additional
medical waste may be added to the remains.
If the operator has chosen a cycle that is too short to completely destroy the
load, simply restart the unit. It is not necessary to add more waste.
Before moving the unit, at least a 30-minute cool-down time should be allowed.
For best results, the manufacturer recommends that ash be removed while the
unit is cool and before the incineration of more waste.
CYCLE COMPLETION
ASH REMOVAL
Ash should be removed before the first burn of the day when the unit is cool,
rather than at the end of the day when the unit is hot.
The supplied rake can be used for removing ash from inside the lower
chamber.