Choosing the power control type
The burner is three-stage. It offers
different possibilities for power
controlling
1. Two-stage regulating with 1
st
stage as an ignition stage and
power controlling between 2
nd
stage
(part-load) and 3
rd
stage (full-load)
Factory wiring, recommended if normal
use of power control ratio
(60-70%:100%), suits to 2-stage power
controllers.
The burner starts in 1
st
stage. After
regulator control release, burner moves
automatically to 2
nd
stage (part-load).
Burner then operates, as a function of
heat request from the boiler regulation,
between 2nd and 3rd stage. In manual
operation, the burner can be adjusted in
either of the three stages.
2. Two-stage regulating with 1
st
stage as ignition stage and
part-load and power controlling
between 1
st
stage (part-load) and
3
rd
stage (full-load), while 2
nd
stage
remains as a changeover stage.
Option "1" in wiring diagram,
recommended if a wide regulation
range is required (over 60% - 100%),
suits to 2-stage power controllers.
The burner starts in 1
st
stage. (Ignition
and part-load). If a higher heat request
comes from the boiler regulation, the
burner switches to 3
rd
stage (full-load).
For a smooth changeover between 1
st
and 3
rd
stage, the 2
nd
stage is used
during the power rise as a straight
through stage.
3. Three-stage regulating with 1
st
stage as both ignition stage and
part-load, 2
nd
stage as medium
high-load, 3
rd
stage as full-load.
Option "2" in wiring diagram, recom
-
mended if a wide regulation range is
required; a three-stage power control
-
ler is required.
The burner starts in 1
st
stage. (Ignition
and part-load) and switches to 2
nd
stage (medium-highload) if a higher
heat request comes from the boiler
regulation, and to 3
rd
stage (full-load) if
a further high heat request comes from
the boiler regulation.
Start-up
Choosing the power control type

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the elco VGL 06.1600 DP and is the answer not in the manual?

elco VGL 06.1600 DP Specifications

General IconGeneral
Brandelco
ModelVGL 06.1600 DP
CategoryBurner
LanguageEnglish

Related product manuals