B. Fill the Rinse Aid DispenserB. Fill the Rinse Aid Dispenser
The rinse aid is released during the final rinse to prevent water from forming droplets on your dishes. That can leave
spots and streaks. It also improves drying by allowing water to sheet off the dishes. Your dishwasher is designed to
use liquid rinse aids. The rinse aid dispenser is located inside the door next to the detergent dispenser. To fill the
dispenser, open the cap and pour the rinse aid into the dispenser until the level indicator turns completely black.
The volume of the rinse aid container is about 110ml.
Rinse Aid Dispenser
Function of Rinse Aid
Rinse aid is automatically added during the last rinse, ensuring thorough rinsing, and spot and streak free drying.
9
Adjusting salt consumption
The dishwasher is designed to allow for adjustment in the amount of salt consumed
based on the hardness of the water used. This is intended to optimise and customise
the level of salt consumption.
Please follow the steps below for adjustment in salt consumption.
WATER HARDNESS
Water
Regeneration
mg/L
softner
occurs
every X program
Saltconsumption
(gram/cycle)
German
French
British
(PPM)
level
dH
fH
Clarke
Mmol/l
sequence
1)
0 - 5 0 - 9 0 - 6
0 - 0.94
0-90
H1
No regeneration
0
6 - 11 10 - 20 7 - 14
1.0 - 2.0
100-200
H2
10
9
12 - 17 21 - 30 15 - 21
2.1 - 3.0
201-300
H3
5
12
18 - 22 31 - 40 22 - 28
3.1 - 4.0
301-400
H4
3
20
23 - 34 41 - 60 29 - 42
4.1 - 6.0
401-600
H5
2
30
35 - 55 61 - 98 43 - 69
6.1 - 9.8
601-980
H6
1
60
1
°
dH=1.25
°
Clarke=1.78
°
fH=0.178mmol/l
The factory setting: H4
1)
Every cycle with a regeneration operation consumes additional 2.0 litres of water,
the energy consumption increases by 0.02 kWh and the program extents by 4
minutes.
1. Close the door, switch on the appliance;
2. Within 60 seconds after the appliance was switched on press the Program
button for more than 5 seconds to enter the water softener setting mode.
3. Press the Program button again to select the proper set according to your local
environment, the setting will change in the following sequence:
H3->H4->H5->H1->H2->H3;