31
Test #
(Model)
Test Name
Components under
test
Test conditions
Displayed
feedback
‘00 Lights / Buttons Test
LEDs, LCD, touch
buttons
The display elements and few
LEDs cycle ON and OFF in a
sequence.
Press LEDs of
touch key or press
Power button.
‘01 Wash Compartment
Door Lock, Hot
Valve
Valve stays ON till water level
reaches 140 mm and the door
remains locked for 5 minutes.*
Water Level
‘02
Bleach
Compartment
Door Lock, Bleach
Valve
Valve stays ON till water level
reaches 140 mm and the door
remains locked for 5 minutes.*
Water Level
‘03
Softener
Compartment
Door Lock, Cold
Valve, Bleach Valve
Valve stays ON till water level
reaches 140 mm and the door
remains locked for 5 minutes.*
Water Level
‘04 Stain Compartment
Door Lock, Pre-
wash Valve
Valve stays ON till water level
reaches 140 mm and the door
remains locked for 5 minutes.*
Water Level
‘05 Door Unlock Drum Light
Drum Light turns ON when the
door is open.
-- --
‘06 Heater and Motor
Pressure Sensor,
Cold Valve, Motor,
NTC, Door Lock
Motor moves after machine fills
60 mm of water. Max. duration
of the test is 8 minutes.
NTC reading
‘07 (41) Empty None None
Display shows n0
for empty test
‘07 (51,61) Recirculation Pump
Recirculation Pump,
Pressure Sensor,
Cold Valve, Motor,
Door Lock, Drum
Light
Motor moves after machine
fills 140 mm of water and
Recirculation Pump turns ON.
Max. duration of the test is 8
minutes.
rP
‘08 (41,51) Empty None None
Display shows n0
for empty test
‘08 (61)
Concentrate Wash
Pump
Concentrate Wash
Pump, Door Lock,
Drum Light
CW Pump turns ON for max. 5
minutes. Need power meter to
check for CW Pump working.
Cp
‘09
Drain Pump and
Spin
Drain Pump, Motor,
Door Lock
Drain Pump turns ON until
empty, then motor starts
spinning until max. RPM for 30
seconds and the door remains
locked for 6 minutes.*
-- --
10 All valves ON
Door Lock, All
Valves
Valves stay ON till water level
reaches 140 mm, then the door
remains locked for 5 minutes.*
Water Level
11 Error History Errors in memory
Errors are displayed in order
of history, displaying the most
recent first. Pressing Temp +
Set keys together clears the
history.
E precedes the
2 character error
code, alternating
through the last 3
errors.
Diagnostic System - EFLS617SIW / EFLS517SIW / EFLS417SIW