12. Function Sequences
12
17 9108
Page
Cool-down
The following conditions must be met for the cool-down valve Y11b (5) to
be energised:
The door must be closed and locked, and the programmer knob must be
in position I (see ”Power supply and start” sequence)
Row M, stop (1) must not be programmed
The out-of-balance switch must not have tripped (breaks K53:51-52 (2)
power supply)
Row K, drain (3) must not be programmed
If the above conditions are met, the cool-down valve Y11b (5) can be
controlled by programming row P (4).