100
Troubleshooting
22:16OVERLOAD
TheMotorControlUnitindicateserrorE.OL.
Overloadcounterhasreached100%.
Theerrorcanonlyberesetafteroverloadcounterhasreached0%again.Thisisindicatedbythe
messageE.nOL.Seealsoerror22:17.
Internalmessage16.
Leavemachinepoweredupwithoutrunninganyprogramfor30minutes.
1.Checkmachineisnotloadedmorethanintended.
2.Checkmotoranddrumformechanicalfault.(jamming).
3.Checkmotorforelectricalfault.
4.Switchoffthemainpowertomachinefor5minutes.
5.Restartthemachine.
22:17NOOVERLOAD
TheMotorControlUnitindicateserrorE.nOL.
Overloadcounterisresetto0%.Seealsoerror22:16.
Internalmessage17.
1.Switchoffthemainpowertomachinefor5minutes.
2.Restartthemachine.
22:18BUS
TheMotorControlUnitindicateserrorE.buS.
Timeoutofmonitoringtimeofcommunicationbetweenoperatorandinverter(Watchdog).
Internalmessage18.
1.Switchoffthemainpowertomachinefor5minutes.
2.Restartthemachine.
22:19OVERLOAD2
TheMotorControlUnitindicateserrorE.OL2.
Standstillconstantcurrentexceeded.
Theerrorcanonlyberesetaftercoolingtimehaselapsed.Thisisindicatedbythemessage
E.nOL2.Seealsoerrorcode22:20.
Internalmessage19.
1.Waituntilmessage22:20,NoERRORoverload2isshown.
2.Switchoffthemainpowertomachinefor5minutes.
3.Restartthemachine.