Technicaldata
9
2.2Technicaldata
W565HW575HW5105HW5130HW5180HW5240HW5300H
Weight,netkg144159201267350400509
Drumvolumelitres65
75
105130180240300
Drumdiameter
mm
520520595650725795795
Drumspeedduringwash
rpm
49494949444242
Drumspeedduring
extraction
rpm
124512451165111510551005950
G-factor,max.
450450450450450450400
Heating:ElectricitykW2.02.05.213182323
kW3.03.0
7.5
kW5.25.210
kW5.45.4
kW
7.57.5
Heating:Steam
xxxxxxx
Heating:Hotwater
xxxxxxx
Frequencyofthedynamic
force
Hz20.820.819.418.617.616.815.8
Floorloadatmax
extraction
kN1.8±0.51.9±0.52.5±0.53.1±0.54.2±1.05.2±1.06.2±1.3
2.3Connections
W565HW575HW5105HW5130HW5180HW5240HW5300H
WatervalvesDN
BSP
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
20
3/4”
Recommendedwater
pressure
kPa200–600200–600200–600200–600200–600200–600200–600
Functioninglimitsfor
watervalve
kPa50–100050–100050–100050–100050–100050–100050–1000
Capacityat300kPal/min
20202020306060
Drainvalve
⌀outer
mm
50/7550/7550/75
75757575
Drainingcapacity
l/min
170170170170170170170
Steamvalveconnection
DN
BSP
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
15
1/2”
Recommendedsteam
pressure
kPa300–600300–600300–600300–600300–600300–600300–600
Functioninglimitsfor
steamvalve