79
MAINDRYER
12:1O.H.THERMOSTAT-INLETAIR
ThiserrorcodeisshowniftheinputO.H.INLETAIRisdeactivated.
Normallythisisduetothatprotectionthermostatforinletairhastriggedduetooverheating.
Theoverheatingthermostatforinletairneedstobemechanicallyrestored.
Whentheoverheatingthermostatforinletairisrestoreditispossibletoresettheerrorcodefrom
thecontrolsystembyashortpressonthecontrolknob/startbuttonandtheongoingprogram
willcontinue.Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemreset
andongoingprogramwillbeended.
Theerrorcodecanbetriggedif:
Theinletairsensorhasstoppedoperatingcorrectly.
Thefanhasstoppedoperating.
Theairowisobstructed,bylint,overload,etc.
Iftheoverheatingthermostatforinletairisnottrigged,buttherestillisanerrorcode:
Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.
12:2O.H.THERMOSTAT-OUTLETAIR
ThiserrorcodeisshowniftheinputO.H.OUTLETAIRisdeactivated.
Normallythisisduetothatprotectionthermostatforoutletairhastriggedduetooverheating.
Theoverheatingthermostatforoutletairneedstobemechanicallyrestored.
Whentheoverheatingthermostatforoutletairisrestoreditispossibletoresettheerrorcodefrom
thecontrolsystembyashortpressonthecontrolknob/startbuttonandtheongoingprogram
willcontinue.Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemreset
andongoingprogramwillbeended.
Theerrorcodecanbetriggedif:
Theoutletairsensorhasstoppedoperatingcorrectly.
Iftheoverheatingthermostatforoutletairisnottrigged,butthereisstillanerrorcode:
Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.