EasyManua.ls Logo

Electrolux W565H - Page 110

Electrolux W565H
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
110
Troubleshooting
40:21I/OCOMMUNICATION
OnlyonBarrierwasher.
TheerrorcodeisactivatedifthecontrolsystemnolongercancommunicatewithBarrierI/Ounitor
ifthecommunicationisintermittent.I/Ounitdesignationthatisshownintheerrordescriptionis
accordingtoelectricschematicsandelectricalcomponentlist.
BarrierI/OboardisconnectedtoM-COMportonCPUinparalellwiththeMCUfordrum.Electrical
interfaceisRS-485.Theerrorcodeisshownifthecontrolsystemhaslostoronlyhaveintermittent
communicationwiththeI/Ounit.
Possiblecauses:
BadcontactinharnessorconnectorsbetweenCPU/MCUandI/Ounit.
TheI/OboardisincorrectlyconguredonDIPswitches(SW210andSW202)
Recommendedactions:
1.Checkwiring,connectionscongurationofI/Ounitaccordingtoservicemanual.
40:22I/OBOARDMISHMASH
TheerrorcodeisshownifwrongTypeofI/Ounitistted.
CouldalsooccurifadressessingoftheI/Ounitsismadeinaincorrectway.
AfteraddressingofI/OunitstheCPUreadstheTypeofeachunit.
IfthereisamismatchbetweenwhattheTypeofI/OunittheCPUnds,andwhattheI/Ounittype
thesoftwarecongurationexpects,theerrorwillbeshown.
Machinewillnotrununtilproblemissolved.Therearetwoexceptions:I/Otype1canbeused
whenI/Otype11isexpected,butnotoposite.I/Otype8canbeusedwhenI/Otype81isexpected,
butnotoposite.
Possiblecauses:
WhenadressingtheI/OunitstheoperatorhaspressedathebuttononthewrongI/Ounit.
WrongtypeofI/Ounitifttedinthemachine.
TwoI/Ounitshavegotthesameadress.
Recommendedactions:
1.ReaddressallI/Ounits.
UseI/OCONFIGURATIONfunctioninservicemode.
AlternativelyuseCommonServiceT ool,I/Oaddressingfunction.
2.UsetheelectricschematictondcorrectI/Oboardtoaddress.
3.UseCommonServiceT ool,I/Oaddressingfunctiontogetbestoverview/visualizationofthe
problem.

Table of Contents

Other manuals for Electrolux W565H

Related product manuals