12:5OUTLETAIRSENSOR-OPEN
TheerrorcodeisshowniftheanaloginputOUTLETAIRTEMP(NTC)isreadingaresistanceof
morethanapproximately26.7kΩ.ProbablycausedbybrokenNTCsensororwiring.
IftheoutletairtemperatureintheSHOWINPUTSmenushowsatemperatureof-10°Ctheoutletair
sensorisopen.
Whentheoutletairsensorisrestoredtheerrorcodeisautomaticallyresetandtheongoing
programwillcontinue.
Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemresetandongoing
programwillbeended.
Theerrorcodecanbetriggedif:
•Thesensor,harnessorconnectorisbroken.Thesensorshallmeasurearound5KOhminroom
temperature,seetable.(Measuredirectoverthesensor).
IfthemeasureofoutletairisOK,butthereisstillanerrorcode:
•Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.
Temp-Sensorresistance
-10°C-26.7kΩ
15°C-7.6kΩ
20°C-6.0kΩ
25°C-4.8kΩ
30°C-3.9kΩ
100°C-0.33kΩ