82 Use instructions
“AMP_026 SWR FOLDBACK”
This indicates that the machine is having a
power reduction since the reflected power
detected is too high.
“AMP_030 OVER 2/3 CARRIER”
This indicates that 2/3 of the power set has
been exceeded.
“AMP_031 PREAMPLIFIER NOT CONNECTED”
This indicates 100% reflected power. Not
implemented here.
“AMP_032 OVER MODULATION”
This indicates over modulation.
“AMP_033 FAST INHIBIT”
This indicates that there are problems on the
hardware lines leading to RF delivery inhibi-
tion.
“AMP_034 TEMPERATURE SENSOR ERROR”
Where there are multiple RF temperature
probes, this indicates that one is faulty if it
measures a noticeably different value from
the other probes.
“AMP_035 PWR FORWARD OSCILLATION”
This indicates oscillations in the output power.
“AMP_036 THREE BLOCK OUT”
This indicates that restore procedure.
“AMP_037 USER ENV TEMP OUT LIMIT”
This indicates a variation with respect to
the conditions set by the user relating to
the ambient temperature measured by the
equipment.
“AMP_038 USER RF TEMP OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the RF
module temperature.
“AMP_039 USER PSU TEMP OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the
power supply temperature.
“AMP_040 USER RF CURRENT OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the RF
module currents.
“AMP_041 USER PSU CURRENT OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the
power supply current.
“AMP_042 USER FRW PWR OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the
direct power.
“AMP_043 USER RFL PWR OUT LIMIT”
This indicates a variation with respect to the
conditions set by the user relating to the
reflected power.
“AMP_044 OUT PWR NOT VERIFIED”
This indicates that the output power cannot
be detected properly.
“AMP_045 UPS ACTIVE”
This indicates that the UPS is active, therefore
the equipment is using the target power set
for operation in this mode.
“AMP_046 SHUNT COMM TIMEOUT”
This indicates the communication timeout
on the polarizer. It stops the operation of the
apparatus.
“AMP_047 WARNING TEMPERATURE SEN-
SOR”
This indicates a fault in the temperature
probes.
“AMP_049 DRAIN VOLTAGE FEEDBACK ER-
ROR”
This indicates the lack of control of Vds for
causes such as power failures, wrong feeding,
etc..
“AMP_050 OVER FRW PWR ERROR”
This indicates the presence of overshoot in
power.
“AMP_051 PILOT PWR GOOD”
This indicates that the driving power is correct
and the driver enabled.
“AMP_052 INCREASE PILOT PWR”
This indicates that the driving power is in the
range below, but close to the range of proper
operation, and the driver is enabled. It is ne-
cessary to a slight increase of the same.
“AMP_053 DECREASE PILOT PWR”
This indicates that the driving power is in the
range top, but close to the range of proper
operation, and the driver is enabled. It is ne-
cessary to a slight decrease of the same.
“AMP_058 RTC FAULT”
This indicates that there were 3 consecutive
mismatches between date/time hardware
and firmware, or the date is formatted incor-
rectly.