bintec elmegBasic settings
Resetting the device to the factory settings
A reset returns all the settings to the default settings. Network configuration, VoIP connections,
directories, call lists and all the individual settings are deleted or restored to the factory settings.
¤ . . . use to select Settings OK Reset OK confirm prompt with Yes
Resetting using the device keys
¤ Disconnect the telephone from the mains power supply press the Control key hold-
ing the key down, reconnect the device with the power supply
Displaying device information
The menu entry Info provides information about important settings on the telephone.
¤ . . . use to select Settings OK Info . . . the following information is
displayed:
Safeguarding personnel settings from the reset: page 38
Resetting the device with the Web configurator page 39
Device: Telephone product name
SW Version: Version of the firmware currently loaded on the phone.
Country Version: Country-specific version of the product
MAC Address LAN: The phone's device address.
IP Address: The phone's current IP address within the local network. The IP address
is usually set automatically via a DHCP server in the network.
There is more information about the settings and the status of the telephone in the
status display of the Web configurator ( page 39).