Service Manual: ET1517L, ET1717L
ES600904 Rev B, Page 32 of 44
2.2. Alignment p or function adjus
The o nt for a L
rocedure (f tment)
list f necessary alignme CD monitor:
Items Description Remark
1 Timing adjustment
Preset timing
2
Auto color balance
adjustment
Timing 114 (VGA480)
HZ(640x480@60
)
Burn-In Mode: ON
Pattern: 5-Mosaic pattern #42
3
Color temperature
t 6500K/Standard adjustmen
9300K/Cool,
7500K
5500K/Warm
2.2.1 Preparation:
1. Setup input timing to any preset modes, any patterns.
2. Enter factory mode (Press “Select” and “Power” button at the same time to turn on monitor)
Press “F” in OSD window left top side)
5. Plug out AC cable
).
tory OSD
(Press “F” in OSD window left top side).
. Select “Auto Color”,
after ADC calibration OK,
factory OSD window will move to middle of
.
meter (or equivalent equipment)
to the required specification listed in Figure-1 below. Manually adjusting R/G/B gain values
in the factory OSD menu.
3. Enter factory OSD (
4. Select Burning ON
6. Setup unit and keep it warm up at least 30 minutes.
2.2.2 Auto color balance adjustment:
1. Setup input
timing #114 VGA480 (640x480@60Hz)
,
pattern #42(5-Mosaic)
with analog
signal from Chroma video pattern generator.
2. Enter factory mode (Press “Select” and “Power” button at the same time to turn on monitor
3. Enter fac
4
screen.
2.2.3 Color temperature adjustment:
1. Setup input timing to any preset modes,
pattern #42(5-Mosaic)
with analog signal from
Chroma video pattern generator.
2. Enter factory mode (Press “Select” and “Power” button at the same time to turn on monitor).
3. Make sure ADC calibration (auto color balance adjustment) had already been done.
Measure and adjust color temperatures by CA-210 spectro4.
US054952 - 2012-09-28T00:54:02Z