Display
Description
Defines the compressor cut-in temperature when added to the set point (SPC
or SPF) temperature during the ready mode.
Considerations
If the differential (dIF) is set too low, for example, less than 2.0°Cthe com-
pressor may cycle on the minimum compressor rest time (rt ).
Range 0.0 to 9.9°C (0 to 18°F)
Global default
4.0°C (7°F)
ems75sz: 3.0°C (5°F)
9.7 Calibration 1 (CA1)
The table below details the calibration 1 (CA1) parameter.
Display
Description
Calibrates or adds an offset to temperatures measured by the appliance
sensor.
Considerations Applied to all temperatures measured on the appliance sensor.
Range
-9.9 to 9.9°C (-18 to 18°F)
-9.9 to 4.0°C (-18 to 18°F) - ems55advanced (UFF d42 firmware only)
Global default 0.0°C (0°F)
9.8 Calibration 2 (CA2)
The table below details the calibration (CA2) parameter.
Display
Description
Calibrates or adds an offset to temperatures measured by the evaporator
sensor. The offset helps the positioning of the evaporator sensor.
Considerations
l Applied to alltemperatures measured on the evaporator sensor.
l Used with ems55advanced OFC firmware.
l Used with the ems75sz controller.
Range -9.9 to 9.9ºC (-18 to 18ºF)
Global default 0.C (0ºF)
9.9 Saving set point (SSP)
The table below details the saving set point (SS P) parameter.
68 of 86
27 February 2014

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Elstat ems75 Sub-Zero and is the answer not in the manual?

Elstat ems75 Sub-Zero Specifications

General IconGeneral
BrandElstat
Modelems75 Sub-Zero
CategoryController
LanguageEnglish

Related product manuals