Display
Description Defines whether the EMS controller uses a 1-day or a 7-day learning period.
Considerations None
Range 00 (1 day) or 01 (7 days)
Global default 00 (1 day)
9.35 Display (dIS)
The table below details the display (dI S) parameter.
Display
Description
Defines whether the EMS controller displays the temperature 3.0, or the word
USE during the ready mode.
EMS controllers always display alarms.
Considerations None
Range 00 (USE) or 01 (temperature)
Global default 01 (temperature)
9.36 Marketing mode (Ar)
The table below details the marketing mode (Ar) parameter.
Display
Description
Sets the cooler lights to remain on at all times for display purposes.
The coolers lights will remain on during saving mode.
Considerations
Does not affect saving temperature.
Only applies to the following controllers:
l ems55advanced and ems55Radvanced - GDC
l ems55advanced and ems55Radvanced - CO2
l ems75sz (sub zero)
l ems55sz (sub zero)
Range 00 (off) or 01 (on)
Global default 00 (off)
9.37 Defrost heater (dHr)
The table below details the defrost heater (dHr) parameter.
78 of 86
27 February 2014