6.3.6 Lights delay (Ld)
Display
Description
Denes the delay to switch o the cooler lights after the controller switches to the
Saving mode.
Considerations
Set in multiples of 30.
Should only take aect once Delay to saving (dS) has completed.
Range 0 to 120 minutes (in multiples of 30 minutes)
Global default 0 (no delay)
6.3.7 Saving restart period (Sr)
Display
Description
Cooler runs at the ready mode temperatures for the duration of this period to ensure
that the product is at the ready mode temperatures prior to retail outlet opening time.
Considerations
Set and veried by OEMs through the test protocol to ensure that product
temperatures are within specication when outlets open.
Set in multiples of 30 minutes.
Range 0 to 240 minutes (in multiples of 30 minutes)
Global default 120 minutes
6.3.8 Refrigeration system failure (Ct)
Display
Description
Denes the maximum continuous runtime of the compressor without reaching the set
point (SP) temperature.
If the set point (SP) temperature is not reached within this time, the controller enters
the RSF Limp home mode.
Considerations None
Range 0 to 100 hours
Global default 72 hours