EasyManua.ls Logo

Elstat Nexo CMS200 - Display (dIS); Marketing mode (Ar); Defrost method (dF)

Default Icon
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Manual, Issue 6 CMS200
www.nexo.comPage 58
6.3.30 Display (dIS)
Display
Description
Denes whether the controller displays the temperature (3.0 for example), or the
word USE during the Ready mode.
Considerations Controllers will always display alarms regardless of the dIS setting.
Range 0 (USE) or 1 (temperature)
Global default 1 (temperature)
6.3.31 Marketing mode (Ar)
Display
Description
Sets the cooler lights to remain on at all times for display purposes. The coolers lights
will remain on during saving mode.
Considerations Does not aect saving temperature.
Range 0 (o) or 1 (on)
Global default 0 (o)
6.3.32 Defrost method (dF)
Display
Description Provides the option for a time-based or temperature-based defrost cycle.
Considerations None
Range 0 (time-based) or 1 (temperature-based)
Global default 0 (time-based)