Environmental requirements
Table 10 list the acceptable environment for both operating and
nonoperating conditions.
Note: The -10° to 40° Celsius range applies to the ambient air temperature at
the air intake vents on the nonport side of the switch. The temperature inside
the switch can be up to 80° Celsius during switch operation.
If the internal temperature range exceeds the operating ranges of the
components, the LEDs, error messages, and Fabric Watch alerts indicate a
problem. Enter the tempShow or Fabric Watch commands to view
temperature status.
Table 10 Environmental Requirements
Condition Acceptable Range During Operation
Acceptable Range During
Non-Operation
Temperature -10° to +40° C (14° to 104° F) -25
° to 70° C (-13° to
158
° F)
Humidity 10% to 85% RH noncondensing, at 40
° C, with
maximum gradient of 10% per hour
10% to 90% RH noncondensing, at 70° C
Altitude 0 to 9,842 ft (3 km) above sea level 0 to 39,370 ft (12 km) above sea level
Shock 20 G, 6 ms duration, half sine wave 33 G, 11 ms duration, half sine
Vibration 0.5 G, 5-500 Hz 2.0 G, 5-500 Hz
Air flow High speed: 23 CFM
Low speed: 18 CFM
None required