5
1. Introduction
Introduction:
“F”and“FA”Seriesmeteringpumpsaretheidealsolutionforlow/middledosing
ofchemicals.Allcontrolandsetupparametersareavailableusingaccurate
controlknobsandavisualsystem(led).“F”and“FA”Seriesmeteringpumps
havedigitalOn/Offswitchtoensuredosingactivities(availableonsomemodels
only).
Pump capacity:
Flowrateisdeterminedbythestrokespeed(frequency)adjustment.Thestroke
speedisadjustablefrom0to100%usingtheadjustmentknob.
Howeverdosingaccuracyisguaranteewithinanadjustmentrangefrom30%to
100%.Theledonthepanelshowsthestatusactivityofthepump.
Feeder should be interlocked with a no-ow protection device to automatically shut-off the
pumps when there is no ow!
Adequate measures shall be taken to prevent cross connection of chemicals!
Chemical feeding must be stopped during backwash cycles and periods of noow as these
conditions may introduce the potential for chemical overdosing. Not doing so may result in
elevated chemical concentrations and hazerdous gas introduction into the pool or spa.
Legend:
a. Alternating Current;
b. DC,
c. Protective Earth;
d. Standby;
e. Warning -
Note for models without main plug only: Theunitshallbeprovidedwitha
ULlisteddisconnectdevice,ratedmin.250V,xxA