EMC-60 User Guide
- 19 -
5.2.20 Command # 20: REMOTE CALL DIALING FREQUENCY
The ‘Remote Dialing Frequency’ controls the remote call feature as follows:
When Remote Dialing Frequency = 1, the EC-Phone dials the remote phone number
once and, upon detecting voice, plays the prompt “This is a diagnostic call to confirm
telephone operation for “Location Announcement” ”, after which the phone announces
the alarm status and hangs-up. The phone hangs up if not answered after 5 rings.
When Remote Dialing Frequency = 2 (daily with descriptive prompt), the EC-Phone
dials the remote phone number, and, upon detecting voice, plays the prompt “This is a
diagnostic call to confirm telephone operation for “Location Announcement” ”, after
which the phone announces the alarm status and hangs-up.
Voice Prompt: “Remote dialing frequency”
5.2.21 Command # 23: SOUNDNET CODE
The “SoundNet Code” is an eleven-digit numeric code describing the elevator number,
branch number, service type and the service contract number. The EC-Phone replays
the DTMF ‘SoundNet Code’ on detecting “# 4” and enters 2-way conversation mode.
The EC-Phone ignores the “#4” digits if “SoundNet Code” is blank.
Voice Prompt: “SoundNet code”
5.2.22 Command # 24: PHONE LINE MONITORING TEST
Enter a value up to 100 to simulate the PLM alarm, de-energizing the relay to activate
the alarm for the number of seconds entered. After the test, the ‘PLM Test’ value resets
to 0.
Voice Prompt: “PLM test”
5.2.23 Command # 30: VOLUME
The ‘Volume Setting’ command sets the speaker volume level.
0 = Very quiet, 9 = Very loud
Voice Prompt: “Speaker volume”
5.2.24 Command # 31: MICROPHONE SENSITIVITY SETTING
This sets the microphone sensitivity. 0 = Least sensitive, 9 = Most sensitive.
Voice Prompt: “Mic sensitivity”