EasyManua.ls Logo

EmerCom Technologies EMC-60 - Programming; Summary Table

EmerCom Technologies EMC-60
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EMC-60 User Guide
- 11 -
5 Programming
5.1 Summary Table
The following section provides more detail information on each command
Cmd
Command Range Default
1 Primary Phone
Number
0 - 23 digits; values 1,2,3,4,5,6,7,8,9,0,#(pause)
Blank = ringdown/consolidator in Lobby mode
Blank
2 Secondary
Phone Number
0 - 23 digits; values 1,2,3,4,5,6,7,8,9,0,#(pause)
Blank = ignore
Blank
3 Third Phone
Number
0 - 23 digits; values 1,2,3,4,5,6,7,8,9,0,#(pause)
Blank = ignore
Blank
4 Location
Announcement
3 seconds minimum; 20 seconds maximum
(message “blank” if < 3 s)
Blank
5 Station Number 1 – 99 1
6 Serial Number
Playback
Replay only Pre-set
7 Firmware
Version
Replay only Pre-set
8 Alarm Status
Playback
Replay only, one or more of the following:
“Normal”
“Charging Battery”
“Low Battery”
“Dead Battery”
“No Battery”
“No Main Power”
“Phone Line Fault”
“Line in use”
“Emergency call not connect – simulate
emergency call to reset”
N/A
9 Access Code 5 digits; values 1,2,3,4,5,6,7,8,9,0 12345
10 Language 0 = English
1 = French
4 = English/Spanish
0