Terminal descriptors for MSIG 1Table 6-4:
J1 J2 J3 J4
CH1
SIG+1/+24 V
CH5
SIG+5/+24 V
CH9
SIG+9/+24 V
TACH1
Tach+1
SIG-1/+24 V return SIG-5/+24 V return SIG-9/+24 V return Tach-1
-24 V -24 V -24 V -24 V
Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return)
Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield)
CH2
SIG+2/+24 V
CH6
SIG+6/+24 V
CH10
SIG+10/+24 V
TACH2
Tach+2
SIG-2/+24 V return SIG-6/+24 V return SIG-10/+24 V return Tach-2
-24 V -24 V -24 V -24 V
Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return)
Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield)
CH3
SIG+3/+24 V
CH7
SIG+7/+24 V
CH11
SIG+11/+24 V
I/O1
I/O+1
SIG-3/+24 V return SIG-7/+24 V return SIG-11/+24 V return I/O-1
-24 V -24 V -24 V -24 V
Gnd (-24 V return
(1)
) Gnd (-24 V return
(1)
) Gnd (-24 V return
(1)
) Gnd (-24 V return
(1)
)
Shield Shield Shield Shield
CH4
SIG+4/+24 V
CH8
SIG+8/+24 V
CH12
SIG+12/+24 V
I/O2
I/O+2
SIG-4/+24 V return SIG-8/+24 V return SIG-12/+24 V return I/O-2
-24 V -24 V -24 V -24 V
Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return) Gnd (-24 V return)
Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield) Chassis GND (Shield)
(1) -24 V terminals on I/O channels are not used for I/O connections.