December 2020
Installation, Operation and Maintenance Manual
VA-DC-000-1878 Rev. 0
42
Section 6: Actuator Support Information
Actuator Support Information
Section 6: Actuator Support Information
6.1 M18 Hydraulic Override System Fluid Volume
Table 11. M18 Hydraulic Override System Fluid Volume
Actuator Size G01 G2 G3 G4 G5 G7 G8 G10
Approximate Volume Fluid
for M18
Quarts 1.6 1.8 2.0 3.6 10.2 9.7 15.9 27.0
Liters 1.8 1.7 1.9 3.4 9.6 9.1 15.1 25.6
6.2 Module Weights by Item Number and
Actuator Housing Size
Table 12. Module Weight by Item Number and Actuator Housing Size
Item
No.
G01
WT.
G2
WT.
G3
WT.
G4
WT.
G5
WT.
G7
WT.
G8
WT.
G10
WT.
Module
Description
1
lb 83 110 162 280 545 1,025 1,495 2,550
Drive Module
kg 38 50 73 127 247 465 678 1,157
3
lb 69 N/A N/A N/A N/A N/A N/A N/A
8” Dia. Power
kg 31 N/A N/A N/A N/A N/A N/A N/A
3
lb 68 80 N/A N/A N/A N/A N/A N/A
9” Dia. Power
kg 30.5 36 N/A N/A N/A N/A N/A N/A
3
lb 75 73.5 88 N/A N/A N/A N/A N/A
10” Dia. Power
kg 34 33 40 N/A N/A N/A N/A N/A
3
lb 86 86 104 130 N/A N/A N/A N/A
12” Dia. Power
kg 39 39 47 59 N/A N/A N/A N/A
3
lb 96 96 114 145 N/A N/A N/A N/A
14” Dia. Power
kg 44 44 51 66 N/A N/A N/A N/A
3
lb N/A 135 145 168 295 N/A N/A N/A
16” Dia. Power
kg N/A 61 66 76 134 N/A N/A N/A
3
lb N/A N/A 235 260 305 585 N/A N/A
20” Dia. Power
kg N/A N/A 107 118 138 265 N/A N/A
3
lb N/A N/A N/A 340 410 735 911 N/A
24” Dia. Power
kg N/A N/A N/A 154 186 334 413 N/A
3
lb N/A N/A N/A 505 590 810 1,225 1,120
28” Dia. Power
kg N/A N/A N/A 229 268 367 556 508
3
lb N/A N/A N/A N/A 977 1,100 1,260 1,440
32” Dia. Power
kg N/A N/A N/A N/A 443 499 572 653
3
lb N/A N/A N/A N/A 1,243 1,400 1,525 1,755
36” Dia. Power
kg N/A N/A N/A N/A 564 653 692 796
3
lb N/A N/A N/A N/A N/A N/A 1,975 2,205
40” Dia. Power
kg N/A N/A N/A N/A N/A N/A 896 1,000
3
lb N/A N/A N/A N/A N/A N/A N/A N/A
44” Dia. Power
kg N/A N/A N/A N/A N/A N/A N/A N/A