92 100-214-251 REV. 05
6.2 Setting Weld Cycle Parameters
When the welder is in the READY state, set parameters by pressing the appropriate
switches on the front panel. Once set, to store the current parameters, press one or both
START SWITCHES, or press RESET.
If you set parameters, start a weld cycle, then hit the EMERGENCY STOP before ending
the cycle, the parameters will be lost.
6.2.1 Selecting a Parameter to Modify
After selecting your weld mode by pressing MODE, press the appropriate switch for the
parameter you wish to modify. For example, press MODE for the Time, Collapse or
Absolute parameters, press HOLD TIME for the Hold Time parameter, then press the
appropriate LIMIT switch to set limits, if necessary.
As you press a switch, its LED will light and the selected parameter’s value will be
displayed in the NUMERIC display.
6.2.2 Modifying Parameter Values
Press the UP/DOWN switches until the value you wish to modify is displayed in the LED
display. Effects of pressing these switches are illustrated in the following Table. In the
Increment Values column, the left side figures indicate effects of pressing SLOW UP/
DOWN switches, while the right side figures indicate effects of pressing FAST UP/DOWN
switches.
If you press an UP/DOWN switch after pressing a parameter selection switch except
MODE, the next press of the parameter selection switch will set the parameter you
selected to is original value. Then the next press will set the parameter to its minimum
value.
Note that you can recall a parameter after you have changed it, but only either before a
weld cycle is run, or before you select another parameter to modify. (For further
information, refer to Section
6.2.4 Recalling Stored Parameters.
Table 6.7 Weld Parameter Values IW+ only
Parameter
Range
Min
Range
Max
Increment Values
SLOW/FAST
Units
Can be
Disabled
Can be
Recalled
Weld Time .050 10.0 .001/.100 sec No No
+ Limit .050 10.0 .001/.100 sec Yes Yes
- Limit .050 10.0 .001/.100 sec Yes Yes
Hold Time .050 10.0 .001/.100 sec No Yes
AB Delay .050 5.00 .001/.100 sec Yes Yes
AB Time .050 1.00 .001/.100 sec Yes Yes
Collapse .0001 0.25 .0001/.0100 inch* No No
+ Limit .0001 0.25 .0001/.0100 inch* Yes Yes
- Limit .0001 0.25 .0001/.0100 inch* Yes Yes
Absolute .0001 4.00 .0001/.0100 inch* No No
+ Limit .0001 4.00 .0001/.0100 inch* Yes Yes
100-214-251 IWoper.book Page 92 Friday, June 16, 2017 4:12 PM