EasyManua.ls Logo

Emerson Branson 2000 Series - Figure 2.3 Front Panel Displays, IW; Table 2.2 Front Panel Displays, IW

Emerson Branson 2000 Series
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 100-214-251 REV. 05
Figure 2.3 Front Panel Displays, IW
Table 2.2 Front Panel Displays, IW
Item Name Function
1 Power Bargraph
This 20 segment bargraph displays the power level
during the Test mode; or the power applied to the
workpiece during a weld cycle. While in READY state,
the graph display the peak power of the last weld cycle.
These readings can be expanded by altering DIP switch
settings. When using the 2x scale, the uppermost
segment will blink. Refer to section 4.11.1 Setting DIP
Switches for further information on DIP settings.
2 Numeric Display
During a weld cycle, indicates the correct weld state
code enabled, or the currently selected parameter’s
value. At the end of the weld cycle, it displays alarms.
3 Up/Down Switches
Once you have selected weld parameters to change,
these four switches increase or decrease your selected
parameters displayed in the NUMERIC DISPLAY. From
left to right, these switches are referred to as the FAST
DOWN switch, the SLOW DOWN switch, the SLOW UP
switch, and the FAST UP switch. Pressing these
switches will have no effect until you have selected
parameters to change. These switches will be disabled
when Display Lock is active.
4 Power Indicator Indicates that power to the welder is on.
5 Reset Switch
Resets any resettable or latchable alarm condition
(indicated by the switch LED blinking). Holding RESET
prevents a weld cycle from starting. Releasing RESET
returns the welder to the READY state, if there are no
non-resettable errors.
100-214-251 IWoper.book Page 22 Friday, June 16, 2017 4:12 PM

Table of Contents

Related product manuals