100-214-251 REV. 05 93
* If you have selected SI units for your application, these values will be in equiv-
alent millimeters.
6.2.3 Storing Parameters
After parameters have been modified, they are stored. Once one or both START
SWITCHES are pressed, then released and the welder enters the READY state, the
parameters are stored. However, if you press the EMERGENCY STOP, or turn the welder
OFF before it enters the READY state, the updated parameters will be lost and the values
previously stored will become the current parameter values.
6.2.4 Recalling Stored Parameters
6.2.4.1Recalling pre-defined parameter values
To recall predefined parameters, as opposed to setting your own exact setting, sit in front
of the welder and press the switch of the parameter (not MODE) that you are modifying as
follows:
press two times consecutively to set the parameter to the minimum value that may be used for
that parameter
press three times to set the parameter to 25% of full scale for that parameter, (This option is not
available for weld time, collapse or absolute distance.)
press four times to disable the parameter (if the parameter can be disabled) or to set the
parameter to its minimum value, if it cannot be disabled
press five times to set the parameter to its minimum value, if the parameter can be disabled
These shortcuts are used to “speed up” navigation of numeric parameters.
Select = Activate parameter for modification
Min. = Set parameter to its minimum value
25% = Set parameter to 25% of full scale
Disable = Disable the function controlled by this parameter. If the function is disabled,
the word OFF will be displayed
- Limit .0001 4.00 .0001/.0100 inch* Yes Yes
Table 6.7 Weld Parameter Values IW+ only (Continued)
Parameter
Range
Min
Range
Max
Increment Values
SLOW/FAST
Units
Can be
Disabled
Can be
Recalled
Table 6.8 Recalling Pre-defined Parameter Values
Parameter Press 1 Press 2 Press 3 Press 4 Press 5
Hold Time Select Min. 25% Press 2 Not used
AB Time/Delay Select Min. 25% Disable Press 2
Limits (±) Select Min. 25% Disable Press 2
100-214-251 IWoper.book Page 93 Friday, June 16, 2017 4:12 PM